IMPORTANT! Read product Safety Data Sheet before use. Always store BG VIA® in a vertical position to prevent spills.
- Start engine and bring to operating temperature. Shut off engine.
- Add 11 oz. (325 mL) of BG Platinum® 44K®, PN 208, to fuel tank.
- Verify that there is no air pressure in the BG VIA® (gauge reads 0 PSI).
- With the ball valve in the OFF position (perpendicular to the line), remove the fill cap on the top of BG VIA® and fill with BG fuel injection cleaner. Replace fill cap, hand tighten.
- Hang BG VIA® on the BG Shop IV Stand, PN 97902-001, and attach air supply.
- Locate and disconnect the fuel feed line from the vehicle.
- Connect BG VIA® to engine side of fuel system with appropriate adaptor.
IMPORTANT! Only connect BG VIA® to the low pressure side on GDI engines! - Block off flow from fuel tank side of fuel system by using appropriate adaptor capped off or by disabling the fuel pump.
- Pressurize BG VIA® by setting air regulator to vehicle-required fuel pressure.
- Open ball valve on BG VIA® and start engine. Make sure all electrical loads are turned off (A/C, blower fan, headlights, etc.).
- Allow engine to run at idle speed until cleaner in BG VIA® is used up and the engine starts to stumble or stalls.
- Remove the air supply from BG VIA.® Press and hold pressure release button on side of BG VIA® until gauge reads 0 PSI.
- Close ball valve and remove BG VIA® and adaptors from engine.
- Reconnect fuel feed line, cycle the ignition on and off several times to prime the fuel system.
- Start engine. Clear any codes that may have set. Road test vehicle.
- Start engine and bring to operating temperature. Shut off engine.
- Add 11 oz. (325 mL) of BG 44K® Platinum,™ to fuel tank. Do not replace fuel cap until after completing service.
- Disable fuel pump. On some systems, the pump must be unplugged at the tank. Removing the fuel pump fuse may disable the ignition system.
- With ball valve in the OFF position (perpendicular to the hose), remove fill cap on the top of BG VIA® and fill with BG fuel injection cleaner. Replace fill cap, hand tighten.
- Hang BG VIA® on BG Shop IV Stand, PN 97902-001, and attach air supply.
- Attach BG VIA® supply hose to test port. On systems without test port, remove fuel line on inlet side of fuel
rail and attach hose using compatible adaptor. - Close off return fuel line with hose pliers or plug line if it cannot be clamped.
- Adjust air regulator to pressurize BG VIA® to approximately 40 PSI.
- Open ball valve and start engine. If engine stumbles after starting, do not tap the throttle! Adjust air regulator to achieve best idle.
- Allow engine to run at idle speed until cleaner in BG VIA® is used up and the engine starts to stumble or stalls.
- Remove hose pliers from return fuel line or remove plug, if used.
- Close ball valve and remove supply hose from fuel rail.
CAUTION! Fuel rail may still be under pressure. - Reconnect inlet fuel line and activate fuel pump.
- Replace cap on fuel tank.
- Start engine. Clear any codes that may have set. Road test vehicle.